Features
- The use of fully ANSI/NEMA tested vacuum breaker in the conversion process

- Parts are stocked by Satin American and the vacuum breaker manufacturer

- The vacuum breakers used for the conversion process have had years of sucessful service

- The circuit breaker to be converted is fully remanufactured prior to the conversion to vacuum
Technical Specifications
- 2,400V - 15,000V
- 600A - 3000A
- 25MVA - 1,000MVA
Services
- Loaner Units Available
- Shipments Available from Stock
Prices: CONTACT US
- By Phone - 1.877-356-5050
- By Email - sales@satinamerican.com
- Online Inquiry - Click Here



One of 6 ITE 5HV-250 Vacuum Replacements.


Westinghouse Siemens and ITE Vacuum replacements, ready to ship from Satin American.
ENGINEERING



ENGINEERING

Engineering is at the forefront of our corporation. Over 20% of SATIN AMERICAN's Employess
are engineers. We have, in the past 75 years, endeavored to service the immediate needs of the Industrial and Utility Markets utilizing engineers to manage this effort.

SATIN AMERICAN employs a staff of fulltime graduates. To assure our customers:
  • That our equipment has been remanufactured with the highest degree of inherent safety.
  • That all codes and standards have been adhered to.
  • That all of our customer's requirements have been filled.
  • That all equipment has been fully tested and the results interpreted.
  • That necessary blueprints and documentation have been provided.



TESTING




TESTING

SATIN AMERICAN fully testsand documents all products prior to shipment. All testing is performed under the direct supervision of out Electrical Engineering Staff. High power lab and ANSI testing is performed on all SATIN AMERICAN designed products.

An Engineer is assigned to each project and will personally sign off on all Electrical and Mechanical Testing:
Typical Testing Includes:
  • Electrical Operation Tests
  • Mechanical Operation Tests
  • Wiring Continuity Tests
  • DC Hypotential
  • AC Hypotential
  • Power Factor(Optional)
  • Speed & Motion Analyzation(Optional)
  • Switchgear Insertion
  • 3 Phase Primary Injection(Switchgear)
  • Loss of Vacuum(Vacuum Only)
  • Overload Coordination(Low Voltage)
  • Relay and Meter Testing(Switchgear)
  • Instrument Transformer Test(Switchgear)
  • Pressure Testing(SF6 only)
  • Corona Analysis(Optional)
  • B.I.L Testing(Optional)




WHAT GOES INTO A VACUUM CONVERSION?
The Art of Retrofitting Air Magnetic Medium Voltage Circuit Breakers With Vacuum and SF6 Components Is Relatively New...

1. Some manufacturers have approached the Retrofitting Process by adding vacuum bottles only to Air Magnetic Frames and existing closing mechanisms. This process can be successful with some stored energy mechanisms when the entire assembly is backed up with ANSI interrupting testing and operational life data.

2. Some manufacturers have retrofitted Solenoid Operated Air Magnetic Circuit Breakers with vacuum bottles only and then claim that the new assemblies are suitable for use. Test data on these closing mechanism and vacuum bottle assemblies may not be available as these components have never been ANSI tested as an assembly.

Claims have been made that these converted breakers have been tested. The only test data available, however, is the data on the vacuum bottles. Lack of overall testing can lead to re-strike and failure of your equipment.

IDENTIFICATION TABLE
Identification Rated Values Related Required Capabilities
ANSI
line
No.
Nominal
rms
Voltage
Class
(kV)
Nominal
3-phase
Class
(MVA)
Rated
Maximum
rms
Voltage
(kV)
Rated
Voltage
Range
Factor
K
Low
Frequency
rms
Voltage
(kV)
Crest
Impulse
Voltage
(kV)
Con-
tinuous
rms
Current
Rating
at 60 Hz
(amperes)
Short-
circuit
rms
Current
Rating
(at Rated
Max kV)
(kA)
Rated
Inter-
rupting
Time
(Cycles)
Rated
Per-
missable
Tripping
Delay, Y
(Seconds)
Rated
Maximum
rms
Voltage
Dividend
by K
Maximum
Symmet-
ncal
Inter-
rupting
Capability
3 Sec
Short
time
Current
Carrying
Capability
Closing
and
Latching
Capability
rms
Current
(kA)
2
3
4.16
4.16
250
250
4.76
4.76
1.24
1.24
19
19
60
60
1200
2000
29
29
3
3
2
2
3.85
3.85
36
36
36
36
58
58
4
5
6
4.16
4.16
4.16
350
350
350
4.76
4.76
4.76
1.0
1.0
1.0
19
19
36
60
60
95
1200
2000
3000
41
41
41
3
3
3
2
2
2
4.16
4.16
4.16
41
41
41
41
41
41
78
78
78
7
8
8
7.2
7.2
7.2
500
500
500
8.25
8.25
8.25
8.25
1.25
1.25
1.25
1.25
36
36
36
36
95
95
95
95
1200
1200
2000
3000
33
33
33
33
3
3
3
3
2
2
2
2
6.6
6.6
6.6
6.6
41
41
41
41
41
41
41
41
66
66
66
78

10
13.8
13.8
500
500
15.0
15.0
1.30
1.30
36
36
95
95
1200
2000
18
18
3
3
2
2
11.5
11.5
23
23
23
23
37
37
11
12

13.8
13.8
13.8
750
750
750
15.0
15.0
15.0
1.30
1.30
1.30
36
36
36
95
95
95
1200
2000
3000
28
28
28
3
3
3
2
2
2
11.5
11.5
11.5
36
36
36
36
36
36
58
58
58
13
14
15
13.8
13.8
13.8
1000
1000
1000
15.0
15.0
15.0
1.30
1.30
1.30
36
36
36
95
95
95
1200
2000
3000
37
37
37
3
3
3
2
2
2
11.5
11.5
11.5
48
48
48
48
48
48
77
77
77