General Electric

In the 1940’s, GENERAL ELECTRIC manufactured its first line of DC circuit breakers and associated switchgear. The models produced were the
  - MC-5  model with amperage ratings to 12000 amp DC
  - MC-6 model with amperage ratings to 12000 amp DC
  - MC-6A model with amperage ratings to 12000 amp DC
  - MC-6B model with amperage ratings to 12000 amp DC

Amperage ratings for the above breakers were 2000, 4000, 6000, 8000, 10000, and 12000 amps DC.

These breakers were controlled by simple electro-mechanical assemblies that afforded, pickup, delay and instantaneous settings. The breakers also had available. Reverse Current tripping features.

The closing mechanism featured a large solenoid operated assembly

The MC series of circuit breakers were available both fixed mounted and drawout. It should be noted that with the fixed model designs, the panel on which the breaker was mounted, came in a number of different dimensions.

The stationary copper for the MC series of breakers, usually folled a standard pattern with regard to size, number of bars and orientation. There were instances, however, when there were deviations from the norm.

You can contact Satin American for specifications on the General Electric copper configurations.

In the mid 1950’s, GENERAL ELECTRIC developed  a series of breakers called the AG6 / AG7. Depending on the designation, the Breakers were available as single pole breakers or MULTIPLE POLE BREAKERS. The multiple pole design afforded the user the opportunity to parallel the poles of the assemblies

The tripping system of the AG series was electromechanical and more complex than that appearing on the MC designs.

The closing mechanism featured a universal motor driven assembly.

If one finds it necessary to order replacements for the AG breakers, please note the number of poles in your request.

Post 2000, GENERAL ELECTRIC took over and began to advance a compact, HIGH SPEED DC BREAKER which was marketed under the name
GERAPID [tm].

The GERAPID series of breakers is compact in design and is controlled by an advanced tripping system.

The breaker carries ratings of 2600, 4200, 6000 and 8000 amps DC. The voltage ratings of the GERAPID breaker extend from 1000 to 3600 volts DC.

The MC and AG series of DC breakers, manufactured by GENERAL ELECTRIC, have been obsoleted.

All of the original Complete GENERAL ELECTRIC MC, AG & GERAPID Circuit Breakers are available directly from the Satin International and Satin American Corp.

Replacement Parts for the majority of GENERAL ELECTRIC circuit breakers and switchgear are in stock and available from Satin International.

Along with Renewal Parts, Satin International maintains an extensive library of original Instruction Books, Sales Catalogs, Blue Print Documentation, and Replacement Parts Information for all Circuit Breakers manufactured GENERAL ELECTRIC

In regards to Replacement and Renewal parts for DC Air Circuit Breakers Satin International Stocks for all generations of equipment:

  - Stationary main contacts, contact kits and contact assemblies,
  - Movable main contacts, contact kits, and each contact assembly,
  - Stationary arcing contacts, contact kits, and contact assemblies,
  - Movable arcing contacts, contact kits, and each contact assembly,
  - Push Rods,
  - Electrical and Manual Operating Mechanisms,
  - Closing Mechanisms, Closing Assemblies,
  - Bushing Assemblies, Pins, Castings, Supports, Barriers, Insulation,
  - Trip Coils, 24 volts dc, 48 volts dc, 125 volts dc, 250 volts dc,
  - Trip Coils, 120 volts ac, 240 volts ac, 480 volts ac
  - Closing Coils, 24 volts dc, 48 volts dc, 125 volts dc, 250 volts dc,
  - Closing Coils, 120 volts ac, 240 volts ac, 480 volts ac
  - Undervoltage Coils and  Undervoltage Devices, 24 volts dc, 48vdc, 125vdc, 250vdc
  - Undervoltage Coils and Undervoltage Devices, 120 volts ac, 240 volts ac, 480 volts ac,
  - Closing relays 24 volts dc, 48 volts dc, 125 volts dc, 250 volts dc,
  - Closing relays 120 volts ac, 240 volts ac, 480 volts ac
  - Anti Pump Relays,
  - Pole Assemblies,
  - Secondary Disconnect Devices and Disconnect Contacts,
  - Primary Disconnect Clusters and Assemblies,
  - Drawout Assemblies, Racking Mechanisms
  - Closing Handles, Escutcheon Plates,
  - Inter Phase Barriers, Porcelain Bottles

CONTACT US

By Phone
Call Us Toll Free
TEL: 877-356-5050

By Fax
FAX: 203-929-9684


By Email
sales@satinamerican.com


On-line
CLICK HERE TO FILL OUT AN ONLINE INQUIRY

REDUCE ARC FLASH TO 0!

With our new etc-12 Digital Solid State Tripping System


Click Here For More Information!


IS YOUR COMPANY NFPA70E COMPLIANT?

SatinAmerican Offers Arc Flash Hazard Safety Training